Security Centres TS2000 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Sicherheitszugriffskontrollsysteme Security Centres TS2000 herunter. GEZE_TS2000_V_Fitting_Instructions Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 6
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
1
GEZE TS 2000 V
Overhead Door Closer
WARNING: DOOR CLOSERS WITH A POWER
RATING LOWER THAN 3 OR WITH MECHANICAL
HOLD OPEN DEVICES ARE NOT SUITABLE FOR
USE WITH FIRE DOORS.
Components Checklist:
1x Closer body & cover
1x Guide Rail Assembly
2x M6 Allen Bolts
2x Plastic end caps
1x Plastic spindle cover
4x 5x55mm Self-tapping countersunk screws
2x M5x40mm Countersunk screws
4x M5x55mm Countersunk screws
2x 5x50 Self-tapping countersunk screws
Tools Required For Installation:
Flat head screwdriver
Posidrive screwdriver
Power drill
4.2mm drill bit
Template (supplied)
Pencil
10mm Spanner
5mm Allen key (supplied)
M5 Tap and Tap wrench
(steel door mounting)
User Information for Door Closers
This information must be observed. Non compliance
will absolve the manufacture from any liability. The
door closer must only be used in accordance with its
intended use; i.e. closing of side hung doors
following manual opening.
Incorrect use may cause injury
¾Obstruction of closing process (e.g. dragging
doors, sticking weather strips/sealing rubbers, rough-
running locks)
¾Incorrect installation and adjustment (e.g.
slamming doors)
¾Danger of finger trap between frame and door leaf.
¾Wrong size door closer.
¾Closer used for other purpose than to close side
hung doors.
Maintenance:
NOTE:
¾Maintenance to be carried out by a specialist only.
¾Check assembly for tolerance and undue wear.
¾Tighten any screws that may have become loose.
At least once a year:
¾Grease moveable parts.
¾Check operation of doors and adjust if necessary.
¾For door closers subject to release by Electro
Mechanical and Electro Hydraulic means ensure that
local regulation are adhered to.
Installation and adjustment by specialist only
Where necessary, an additional doorstop or buffer
must be fitted to limit the maximum opening of the
door. This is of particular relevance for slide rail
closers where the opening angle may be limited by
frame. For further explanations see catalogue
preface and product information.
Door handing - DIN left / right
Stand facing the door on the hinge side / pull side. If the hinge or
pivot is to your right hand side the door is considered to be DIN
right. If the hinge or pivot is to your left hand side the door is
considered to be DIN left.
IMPORTANT WARNING:
HIGH INTERNAL PRESSURES, UNDER NO CIRCUMSTANCES
ATTEMPT TO DISMANTLE THE CLOSER.
TS2000 BODY
Latch action valve ( TS2000 BC only )
Closing speed valve
226
60
48
2
4
5
Spindle
285
a
p
p
r
o
x
.
3
0
0
SECONDARY ARM
PRIMARY ARM
20
16
58
TS2000 PARALLEL ARM BRACKET
95 28
4
Installation Instructions
Seitenansicht 0
1 2 3 4 5 6

Inhaltsverzeichnis

Seite 1 - Overhead Door Closer

1GEZE TS 2000 VOverhead Door CloserWARNING: DOOR CLOSERS WITH A POWERRATING LOWER THAN 3 OR WITH MECHANICALHOLD OPEN DEVICES ARE NOT SUITABLE FORUSE

Seite 2 - Fixing in figure 1

244384760Fig380°Fig4Fig590°90°Fixing in figure 122245344319Power size 4Power size 229460Power size 513544130135452226013044344319294Power size 5Power

Seite 3 - Fixing in figure 61

34438604722245294319344Power size 5Power size 2Power size 4135601304445222344Power size 5319294Power size 2130Power size 4601354480°Fig390°Fig4Fig590°

Seite 4 - Fixing in figure 66

46044384726028831060Power size 513544Power size 2Power size 444444460310285260Power size 4Power size 5Power size 2135¾Mark the fixing positions in acc

Kommentare zu diesen Handbüchern

Keine Kommentare